              DN15-50mm, threads end
              DN50-500, Flanged end
              Woltmann
              Combine
              Irrigation
              Accessories
               
              Irrigation
               
              WIV/LA-80~250E (with pulser)
               

              This type of water meter also can be used for a remote reading transmission system as equipped with a built-in sensor.
              APPLICATION: To totalize the total volume of cold (hot) water passing through the pipeline.
              WORKING CONDITION:
              The max.admissible water pressure: 1.6MPa.
              Water temperature: 0.1℃~50℃.
              FEATURES:
              --The water meters of this series were especially designed to give a reliable measurement of waters carrying also solid particles.
              --Head lose of the meters are negligible, enabling efficient operation to be maintained where only a limited head of water is available.
              --The body and cap flange are coated by an epoxy varnish treatment to insure better anticorrosive effect during long service time.
              --Capsulated counter can give clear reading even when the water is dirty; Reed contact for remote reading can supplied upon request。
              --The self-cleaning propeller of three blade design avoids clogging by grass or other solid particles held in the water; The measuring mechanism is robust in construction with few moving parts subject to wear, and can be easily removed for inspection and maintenance。 --The meters are very suitable for irrigated water and can be employed also for intermittent or seasonal services. Upon request, the water meter could be equipped with a kind of remote transmission device. Pulse output has 100L/P and 1000L/P to choice.
              MAXIMUM PERMISSIBLE ERROR:
              From transitional flow up to maximum flow both inclusive: ±2%;
              From minimum flow inclusive up to transitional flow: ±5%.
              FLOW-ERROR CURVE     PRESURE LOSS-ERROR CURVE
              DIMENSIONS AND WEIGHTS

              Size

              Length
              L

              Width
              B

              Height
              H1

              Height
              H2

              Outer Diameter
              D1

              Bolt Circle Diameter D2

              Connecting
              Bolt

              Weight

              mm

              n-Md

              Kg

              80

              280

              200

              275

              435

              200

              160

              8-M16

              34.5

              100

              280

              220

              325

              486

              220

              180

              8-M16

              37

              125

              350

              250

              320

              496

              250

              210

              8-M16

              40

              150

              360

              285

              350

              533

              285

              240

              8-M20

              47.5

              200

              300

              340

              328

              542

              340

              295

              12-M20

              73

              250

              300

              405

              353

              592

              405

              355

              12-M24

              100


              MAIN TECHNICAL DATA

              Size
              mm

              CLASS

              Maximum
              flow

              Nominal
              flow

              Transitional
              flow

              Minimum
              Flow

              Minimum
              Reading

              Maximum
              Reading

              m3/h

              m3

              80

              A

              70

              35

              14

              8.5

              0.01

              999999

              B

              12

              7.0

              100

              A

              120

              60

              22

              11

              0.01

              999999

              B

              18

              9.0

              125

              A

              160

              80

              36

              14

              0.01

              999999

              B

              30

              12

              150

              A

              270

              150

              54

              19

              0.01

              999999

              B

              45

              16

              200

              A

              400

              290

              90

              58

              0.01

              999999

              B

              75

              55

              250

              A

              700

              450

              140

              90

              0.01

              999999

              B

              120

              85


              BOUNDARY DIMENSION

               

                All rights reserved: Lianyungang Lianli Water Meter Co.,Ltd. Tel: 0086-518-82341113 Fax: 0086-518-82340789
              Add: Lianyungang economic and technological development zone, jiangsu, china
              P.C: 222047 E-mail : lianli@lianliwm.com Support: Sooba.cn 